MSB – Modbus sensor box

Signal converter (Voltage, Pt100 and Frequency) to RS485 with Modbus RTU protocol

Modbus Sensor Box is a sensor conditioning unit to convert (Volt, Pt100 e Hz) signals into RS485 over RTU Modbus protocol. Modbus sensor box can receive signals from different sensors on the market as: solar irradiance sensor, also pyranometers (configurable sensitivity value), temperature sensors (Pt100) and wind speed sensor (Hz).
Input for Storm distance sensor.


  • N.1 high-resolution input (18 bit) for Pyranometer/reference cell (μV, mV) or 0÷1V. Configurable pyranometer sensitivity value;
  • N.2 Pt100 inputs (3-wire) with 0.5°C accuracy;
  • N.1 included internal Pt100 temperature sensor as alternative to external sensor;
  • N.1 pulse/frequency input for LSI LASTEM wind speed sensors (DNA202-30x);
  • N.1 RS232 input for Storm Distance Sensor (DQA601.1);
  • Output: instant value and current statistical values (min/avg/max, tot.) for every channel over programmable time base;
  • 9÷30 Vdc Power Supply;
  • IP66 protection grade.
  • N.1 RS232 port on board for configuration using Terminal Emulation program;
  • N.1 porta RS485: protocollo Modbus RTU® con protezione galvanica;
  • Model code: DSA501.

Documents

This document is not available for download, please contact our Sales Department.

Description


  • N.1 high-resolution input (18 bit) for Pyranometer/reference cell (μV, mV) or 0÷1V. Configurable pyranometer sensitivity value;
  • N.2 Pt100 inputs (3-wire) with 0.5°C accuracy;
  • N.1 included internal Pt100 temperature sensor as alternative to external sensor;
  • N.1 pulse/frequency input for LSI LASTEM wind speed sensors (DNA202-30x);
  • N.1 RS232 input for Storm Distance Sensor (DQA601.1);
  • Output: instant value and current statistical values (min/avg/max, tot.) for every channel over programmable time base;
  • 9÷30 Vdc Power Supply;
  • IP66 protection grade.
  • N.1 RS232 port on board for configuration using Terminal Emulation program;
  • N.1 porta RS485: protocollo Modbus RTU® con protezione galvanica;
  • Model code: DSA501.

Additional information

Applications

, , , , , , , ,

Reviews

There are no reviews yet.

Be the first to review “MSB – Modbus sensor box”

Your email address will not be published. Required fields are marked *

Post comment

This document is not available for download, please contact our Sales Department.

Description


  • N.1 high-resolution input (18 bit) for Pyranometer/reference cell (μV, mV) or 0÷1V. Configurable pyranometer sensitivity value;
  • N.2 Pt100 inputs (3-wire) with 0.5°C accuracy;
  • N.1 included internal Pt100 temperature sensor as alternative to external sensor;
  • N.1 pulse/frequency input for LSI LASTEM wind speed sensors (DNA202-30x);
  • N.1 RS232 input for Storm Distance Sensor (DQA601.1);
  • Output: instant value and current statistical values (min/avg/max, tot.) for every channel over programmable time base;
  • 9÷30 Vdc Power Supply;
  • IP66 protection grade.
  • N.1 RS232 port on board for configuration using Terminal Emulation program;
  • N.1 porta RS485: protocollo Modbus RTU® con protezione galvanica;
  • Model code: DSA501.

Additional information

Applications

, , , , , , , ,

Reviews

There are no reviews yet.

Be the first to review “MSB – Modbus sensor box”

Your email address will not be published. Required fields are marked *

Post comment

Related products