This document is not available for download, please contact our Sales Department.
MSB – Modbus sensor box
Signal converter (Voltage, Pt100 and Frequency) to RS485 with Modbus RTU protocol
Modbus Sensor Box is a sensor conditioning unit to convert (Volt, Pt100 e Hz) signals into RS485 over RTU Modbus protocol. Modbus sensor box can receive signals from different sensors on the market as: solar irradiance sensor, also pyranometers (configurable sensitivity value), temperature sensors (Pt100) and wind speed sensor (Hz).
Input for Storm distance sensor.
MSB – Modbus sensor box
Highlights
- N.1 high-resolution input (18 bit) for Pyranometer/reference cell (μV, mV) or 0÷1V. Configurable pyranometer sensitivity value;
- N.2 Pt100 inputs (3-wire) with 0.5°C accuracy;
- N.1 included internal Pt100 temperature sensor as alternative to external sensor;
- N.1 pulse/frequency input for LSI LASTEM wind speed sensors (DNA202-30x);
- N.1 RS232 input for Storm Distance Sensor (DQA601.1);
- Output: instant value and current statistical values (min/avg/max, tot.) for every channel over programmable time base;
- 9÷30 Vdc Power Supply;
- IP66 protection grade.
- N.1 RS232 port on board for configuration using Terminal Emulation program;
- N.1 porta RS485: protocollo Modbus RTU® con protezione galvanica;
- Model code: DSA501.
Documents
Description
MSB – Modbus sensor box
Highlights
- N.1 high-resolution input (18 bit) for Pyranometer/reference cell (μV, mV) or 0÷1V. Configurable pyranometer sensitivity value;
- N.2 Pt100 inputs (3-wire) with 0.5°C accuracy;
- N.1 included internal Pt100 temperature sensor as alternative to external sensor;
- N.1 pulse/frequency input for LSI LASTEM wind speed sensors (DNA202-30x);
- N.1 RS232 input for Storm Distance Sensor (DQA601.1);
- Output: instant value and current statistical values (min/avg/max, tot.) for every channel over programmable time base;
- 9÷30 Vdc Power Supply;
- IP66 protection grade.
- N.1 RS232 port on board for configuration using Terminal Emulation program;
- N.1 porta RS485: protocollo Modbus RTU® con protezione galvanica;
- Model code: DSA501.
Additional information
Applications | Agro-meteorology, Air quality, Airports and roads, Hydrology, Meteo observations, Museums and archaeological sites, Ports and railways, Renewable energies, Waste cycle |
---|
This document is not available for download, please contact our Sales Department.
Description
MSB – Modbus sensor box
Highlights
- N.1 high-resolution input (18 bit) for Pyranometer/reference cell (μV, mV) or 0÷1V. Configurable pyranometer sensitivity value;
- N.2 Pt100 inputs (3-wire) with 0.5°C accuracy;
- N.1 included internal Pt100 temperature sensor as alternative to external sensor;
- N.1 pulse/frequency input for LSI LASTEM wind speed sensors (DNA202-30x);
- N.1 RS232 input for Storm Distance Sensor (DQA601.1);
- Output: instant value and current statistical values (min/avg/max, tot.) for every channel over programmable time base;
- 9÷30 Vdc Power Supply;
- IP66 protection grade.
- N.1 RS232 port on board for configuration using Terminal Emulation program;
- N.1 porta RS485: protocollo Modbus RTU® con protezione galvanica;
- Model code: DSA501.
Additional information
Applications | Agro-meteorology, Air quality, Airports and roads, Hydrology, Meteo observations, Museums and archaeological sites, Ports and railways, Renewable energies, Waste cycle |
---|
Reviews
There are no reviews yet.
Reviews