{"id":94309,"date":"2024-01-23T16:09:57","date_gmt":"2024-01-23T15:09:57","guid":{"rendered":"https:\/\/34.22.187.232\/?post_type=product&#038;p=94309"},"modified":"2026-10-27T14:52:56","modified_gmt":"2026-10-27T13:52:56","slug":"piranometri-di-classe-a","status":"publish","type":"product","link":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/","title":{"rendered":"Piranometri di Classe A"},"content":{"rendered":"\r\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\r\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"font-size: 40px;\">\r\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\r\n<h2 class=\"wp-block-heading has-text-color has-link-color wp-elements-1\" style=\"color: #565656; font-size: 18px;\"><em><strong>Piranometri di Classe A<\/strong><\/em><\/h2>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading has-text-color has-link-color wp-elements-2\" style=\"color: #565656; font-size: 35px;\"><strong>Caratteristiche<\/strong><\/h2>\r\n<\/div>\r\n\r\n\r\n<hr class=\"wp-block-separator has-text-color has-alpha-channel-opacity has-background\" style=\"background-color: #e5231a; color: #e5231a;\" \/><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-spacer\" style=\"height: 35px;\" aria-hidden=\"true\">\u00a0<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\r\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis: 49%;\">\r\n<ul id=\"block-e1057b77-0dad-4f99-b9ea-156274e90ab8\" class=\"wp-block-list\">\r\n<li style=\"font-size: 17px;\">Piranometri spectrally flat Class A conformi a ISO 9060:2018<\/li>\r\n\r\n\r\n\r\n<li>Sensori ideali per il monitoraggio della performance dei pannelli solari e reti meteorologiche<\/li>\r\n\r\n\r\n\r\n<li>Diverse tipologie di uscite (\u03bcV, 4\u202620 mA, RS485)<\/li>\r\n<\/ul>\r\n<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\u00a0<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis: 49%;\">\r\n<ul id=\"block-e1057b77-0dad-4f99-b9ea-156274e90ab8\" class=\"wp-block-list\">\r\n<li style=\"font-size: 17px;\">Calibrazione tracciabile al WRR<\/li>\r\n\r\n\r\n\r\n<li>Modello con Tecnologia RVH (Recirculating Ventilation<\/li>\r\n\r\n\r\n\r\n<li>and Heating) e misura dell\u2019angolo di inclinazione (DPA953.1)<\/li>\r\n\r\n\r\n\r\n<li style=\"font-size: 17px;\">Codici modelli: DPA252.2, DPA952.3, DPA953.1, DPA952.1.<\/li>\r\n<\/ul>\r\n<\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-spacer\" style=\"height: 20px;\" aria-hidden=\"true\">\u00a0<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-spacer\" style=\"height: 50px;\" aria-hidden=\"true\">\u00a0<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\r\n<p class=\"has-text-color has-link-color has-large-font-size wp-elements-3 wp-block-paragraph\" style=\"color: #565656;\"><strong>FAQ: Frequently Asked Questions<\/strong><\/p>\r\n\r\n\r\n<hr class=\"wp-block-separator has-text-color has-alpha-channel-opacity has-background\" style=\"background-color: #e5231a; color: #e5231a;\" \/><\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-spacer\" style=\"height: 41px;\" aria-hidden=\"true\">\u00a0<\/div>\r\n\r\n\r\n\r\n<div><details style=\"border-bottom: 1px solid #e6e6e6; padding: 12px 0;\">\r\n<summary style=\"cursor: pointer; font-weight: bold; font-size: 18px; color: #444;\">Perch\u00e9 scegliere un piranometro di Classe A?<\/summary>\r\n<p style=\"font-size: 15px; font-weight: 400; margin-top: 10px; color: #444;\">Un piranometro di Classe A \u00e8 indicato quando sono richieste misure dell\u2019irraggiamento solare con elevata accuratezza, stabilit\u00e0 e affidabilit\u00e0 nel tempo. Rispetto alle classi inferiori, presenta requisiti pi\u00f9 stringenti per risposta direzionale, dipendenza dalla temperatura, non linearit\u00e0 e stabilit\u00e0, risultando adatto al monitoraggio fotovoltaico, alla meteorologia e alla ricerca scientifica.<\/p>\r\n<\/details><details style=\"border-bottom: 1px solid #e6e6e6; padding: 12px 0;\">\r\n<summary style=\"cursor: pointer; font-weight: bold; font-size: 18px; color: #444;\">Perch\u00e9 i piranometri di Classe A sono importanti negli impianti fotovoltaici?<\/summary>\r\n<p style=\"font-size: 15px; font-weight: 400; margin-top: 10px; color: #444;\">La misura accurata dell\u2019irraggiamento permette di confrontare l\u2019energia solare disponibile con quella effettivamente prodotta dall\u2019impianto. Un piranometro di Classe A aiuta quindi a valutare performance, perdite e anomalie con maggiore affidabilit\u00e0, soprattutto nei grandi impianti e nelle applicazioni in cui piccoli errori di misura possono influire sull\u2019analisi della resa energetica.<\/p>\r\n<\/details><details style=\"border-bottom: 1px solid #e6e6e6; padding: 12px 0;\">\r\n<summary style=\"cursor: pointer; font-weight: bold; font-size: 18px; color: #444;\">Perch\u00e9 utilizzare un piranometro di Classe A nella ricerca scientifica?<\/summary>\r\n<p style=\"font-size: 15px; font-weight: 400; margin-top: 10px; color: #444;\">Nella ricerca servono dati accurati, ripetibili e confrontabili tra siti, strumenti e periodi differenti. La ridotta incertezza, la risposta spettrale piatta e la calibrazione tracciabile al World Radiometric Reference rendono i piranometri di Classe A LSI LASTEM adatti a studi climatici, analisi radiometriche, reti meteorologiche e validazione di modelli ambientali ed energetici.<\/p>\r\n<\/details><details style=\"border-bottom: 1px solid e6e6e6; padding: 12px 0;\">\r\n<summary style=\"cursor: pointer; font-weight: bold; font-size: 18px; color: #444;\">A quali norme sono conformi i piranometri di Classe A LSI LASTEM?<\/summary>\r\n<p style=\"font-size: 15px; font-weight: 400; margin-top: 10px; color: #444;\">I piranometri LSI LASTEM sono classificati Spectrally Flat Class A secondo ISO 9060:2018 e sono progettati in coerenza con le indicazioni della WMO No. 8, Parte I, Capitolo 7, dedicate alla misura della radiazione solare. La calibrazione tracciabile al WRR e la disponibilit\u00e0 di uscite \u03bcV, 4\u201320 mA e RS485 facilitano inoltre l\u2019integrazione in sistemi di monitoraggio meteorologico, fotovoltaico e scientifico.<\/p>\r\n<\/details><details style=\"border-bottom: 1px solid e6e6e6; padding: 12px 0;\">\r\n<summary style=\"cursor: pointer; font-weight: bold; font-size: 18px; color: #444;\">Quali vantaggi offre il laboratorio LSI LASTEM accreditato ISO\/IEC 17025?<\/summary>\r\n<p style=\"font-size: 15px; font-weight: 400; margin-top: 10px; color: #444;\">LSI LASTEM dispone di un laboratorio interno accreditato ACCREDIA secondo la norma ISO\/IEC 17025 per la taratura degli strumenti di misura dell\u2019irradianza solare. Questo permette di fornire certificati di taratura metrologicamente riferibili, utili per verificare le prestazioni del piranometro, mantenere sotto controllo l\u2019incertezza di misura e garantire nel tempo dati affidabili per impianti fotovoltaici, reti meteorologiche e attivit\u00e0 di ricerca.<\/p>\r\n<\/details><\/div>\r\n","protected":false},"excerpt":{"rendered":"<p><strong>Sensori per la misura dell\u2019irraggiamento globale<\/strong><\/p>\n<p>Radiometri per la misura dell\u2019irraggiamento solare secondo la normativa ISO 9060 e WMO N. 8 (Parte I, Capitolo 7). Questi sensori sono classificati come Classe A ISO9060. Con un&#8217;incertezza giornaliera totale di solo il 2%, tempi di risposta rapidi, questi sensori sono ideali per gli utenti che richiedono accuratezza e affidabilit\u00e0 di alto livello.<\/p>\n","protected":false},"featured_media":125358,"template":"","meta":[],"product_brand":[],"product_cat":[297,432,298],"product_tag":[],"class_list":["post-94309","product","type-product","status-publish","has-post-thumbnail","product_cat-radiazione-solare","product_cat-sensori","product_cat-sensori-meteo","pa_applicazione-aeroporti-e-strade","pa_applicazione-agro-meteorologia","pa_applicazione-ciclo-del-rifiuto","pa_applicazione-energie-rinnovabili","pa_applicazione-idrologia","pa_applicazione-musei-e-siti-archeologici","pa_applicazione-osservazioni-meteo","pa_applicazione-qualita-dellaria","pa_applicazione-stress-e-comfort-termico-indoor-e-outdoor-fisso","pa_grandezze-radiazione-solare","pa_modelli-uscita-analogica","pa_modelli-uscita-analogica-dpa952-2","pa_modelli-uscita-diretta","pa_modelli-uscita-diretta-dpa252-2","pa_modelli-uscita-modbus-rs485-dpa952-3","pa_modelli-uscita-rs485-modbus","description-off","first","instock","purchasable","product-type-variable","has-default-attributes"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Piranometri di Classe A - LSI LASTEM<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Piranometri di Classe A - LSI LASTEM\" \/>\n<meta property=\"og:description\" content=\"Sensori per la misura dell\u2019irraggiamento globaleRadiometri per la misura dell\u2019irraggiamento solare secondo la normativa ISO 9060 e WMO N. 8 (Parte I, Capitolo 7). Questi sensori sono classificati come Classe A ISO9060. Con un&#039;incertezza giornaliera totale di solo il 2%, tempi di risposta rapidi, questi sensori sono ideali per gli utenti che richiedono accuratezza e affidabilit\u00e0 di alto livello.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/\" \/>\n<meta property=\"og:site_name\" content=\"LSI LASTEM\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-27T13:52:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lsi-lastem.com\/wp-content\/uploads\/piranometri-di-Classe-A-RADIAZIONE-SOLARE-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1100\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/piranometri-di-classe-a\\\/\",\"url\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/piranometri-di-classe-a\\\/\",\"name\":\"Piranometri di Classe A - LSI LASTEM\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/piranometri-di-classe-a\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/piranometri-di-classe-a\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lsi-lastem.com\\\/wp-content\\\/uploads\\\/piranometri-di-Classe-A-RADIAZIONE-SOLARE-1.webp\",\"datePublished\":\"2024-01-23T15:09:57+00:00\",\"dateModified\":\"2026-10-27T13:52:56+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/piranometri-di-classe-a\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/piranometri-di-classe-a\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/piranometri-di-classe-a\\\/#primaryimage\",\"url\":\"https:\\\/\\\/lsi-lastem.com\\\/wp-content\\\/uploads\\\/piranometri-di-Classe-A-RADIAZIONE-SOLARE-1.webp\",\"contentUrl\":\"https:\\\/\\\/lsi-lastem.com\\\/wp-content\\\/uploads\\\/piranometri-di-Classe-A-RADIAZIONE-SOLARE-1.webp\",\"width\":1100,\"height\":630},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/piranometri-di-classe-a\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Prodotti\",\"item\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/prodotti\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Piranometri di Classe A\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/\",\"name\":\"LSI LASTEM\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/lsi-lastem.com\\\/it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Piranometri di Classe A - LSI LASTEM","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/","og_locale":"it_IT","og_type":"article","og_title":"Piranometri di Classe A - LSI LASTEM","og_description":"Sensori per la misura dell\u2019irraggiamento globaleRadiometri per la misura dell\u2019irraggiamento solare secondo la normativa ISO 9060 e WMO N. 8 (Parte I, Capitolo 7). Questi sensori sono classificati come Classe A ISO9060. Con un'incertezza giornaliera totale di solo il 2%, tempi di risposta rapidi, questi sensori sono ideali per gli utenti che richiedono accuratezza e affidabilit\u00e0 di alto livello.","og_url":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/","og_site_name":"LSI LASTEM","article_modified_time":"2026-10-27T13:52:56+00:00","og_image":[{"width":1100,"height":630,"url":"https:\/\/lsi-lastem.com\/wp-content\/uploads\/piranometri-di-Classe-A-RADIAZIONE-SOLARE-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"3 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/","url":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/","name":"Piranometri di Classe A - LSI LASTEM","isPartOf":{"@id":"https:\/\/lsi-lastem.com\/it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/#primaryimage"},"image":{"@id":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/#primaryimage"},"thumbnailUrl":"https:\/\/lsi-lastem.com\/wp-content\/uploads\/piranometri-di-Classe-A-RADIAZIONE-SOLARE-1.webp","datePublished":"2024-01-23T15:09:57+00:00","dateModified":"2026-10-27T13:52:56+00:00","breadcrumb":{"@id":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/#primaryimage","url":"https:\/\/lsi-lastem.com\/wp-content\/uploads\/piranometri-di-Classe-A-RADIAZIONE-SOLARE-1.webp","contentUrl":"https:\/\/lsi-lastem.com\/wp-content\/uploads\/piranometri-di-Classe-A-RADIAZIONE-SOLARE-1.webp","width":1100,"height":630},{"@type":"BreadcrumbList","@id":"https:\/\/lsi-lastem.com\/it\/prodotti\/piranometri-di-classe-a\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lsi-lastem.com\/it\/"},{"@type":"ListItem","position":2,"name":"Prodotti","item":"https:\/\/lsi-lastem.com\/it\/prodotti\/"},{"@type":"ListItem","position":3,"name":"Piranometri di Classe A"}]},{"@type":"WebSite","@id":"https:\/\/lsi-lastem.com\/it\/#website","url":"https:\/\/lsi-lastem.com\/it\/","name":"LSI LASTEM","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lsi-lastem.com\/it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"}]}},"_links":{"self":[{"href":"https:\/\/lsi-lastem.com\/it\/wp-json\/wp\/v2\/product\/94309","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lsi-lastem.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lsi-lastem.com\/it\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lsi-lastem.com\/it\/wp-json\/wp\/v2\/media\/125358"}],"wp:attachment":[{"href":"https:\/\/lsi-lastem.com\/it\/wp-json\/wp\/v2\/media?parent=94309"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lsi-lastem.com\/it\/wp-json\/wp\/v2\/product_brand?post=94309"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lsi-lastem.com\/it\/wp-json\/wp\/v2\/product_cat?post=94309"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lsi-lastem.com\/it\/wp-json\/wp\/v2\/product_tag?post=94309"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}